Модульная очистка Чистая комната чистая чистые кабины с различной чистоты уровня


Поделиться:

Цена:*
Стоимость в USD (на сегодня):Узнать

Количество:

Описание и отзывы

Характеристики



Product Description




Modular Cleanroom Configuration
(1) The modular cleanroom exterior is made of industrial-grade aluminum or stainless steel that is sturdy, resistant to rust, and
does not collect dust.
(2) The exterior is covered with anti-static material (often acrylic board) that is highly transparent, pliable and durable.
(3) Fan Filter Units (FFU) employ a centrifugal fan, may run at a variety of different speeds, are easy to maintain, give off low
vibration and noise levels, and are very durable. FFUs are the engine behind the air purification function of the cleanroom, and
E-Clean's new FFUs are specially designed to operate quietly. Our FFUs are compatible with cleanrooms from FS209E levels
100-100,000 and ISO levels 5-8.
(4) Our modular cleanrooms only use lights approved for cleanroom applications. These lights do not produce any dust.

Modular Cleanroom Air Velocity Control
The airflow in a modular cleanroom is a very important factor in the overall performance of the cleanroom. Most cleanrooms have anaverage air velocity of between 0.25-0.5 m/s. This is a relatively low air velocity, and therefore has the potential to be interrupted or disturbed by people and/or machinery within the cleanroom. On the other hand, raising the air speed too high will increase operational costs. When deciding upon the air speed to set within a cleanroom, an enterprise must first confirm that the selected air speed will be able to maintain an environment that meets cleanliness standards. However, the air speed required to meet these requirements should not be exceeded by too much, otherwise you will incur unnecessary costs.
Besides determining the appropriate air velocity, steps must be taken to maintain a constant airflow and velocity. Otherwise, it is possible for air to build up around the walls and form a sort of vortex. If this occurs it is extremely difficult to cycle the air in and out of the room, and thus nearly impossible to maintain a clean environment.
In order for a laminar airflow cleanroom to maintain constant, uniform airflow, all fans must be set to the same speed.
Additionally, if the air speed falls outside of the 0.25-0.5 m/s range, it is also possible for vortex-like air patterns to occur
in the cleanroom.





Advantages of E-Clean Modular Cleanrooms
(1) Can be used independently or as a component of a clean area
(2) Lower fixed costs, easier installation, and quicker turnaround than a permanent cleanroom
(3) Modular structure allows for easy adjustment of cleanliness level, scalability, and reutilization
(4) Attachable wheels allow for convenient mobility

Maintaining your Modular Cleanroom
(1) Regularly wipe surfaces with alcohol clean wipes to maintain cleanliness.
(2) Ensure more than one power source is available to the cleanroom. That way your operation is not compromised in the event of a power failure.
(3) Stress the importance of not coming into contact with any filtration equipment to your employees. Take precautions to avoid
excessive contact with the anti-static curtains.
(4) Personnel should only wear approved cleanroom apparel, including shoes and masks, to avoid contamination risk.
(5) The fans in the cleanroom should be turned on for at 10 minutes before any personnel are allowed to enter.

Optimizing the Performance of your Modular Cleanroom
Many factors influence the performance of a cleanroom. From machinery to staff, to the materials used in the construction of the
cleanroom, to seemingly insignificant factors such as the light fixtures. One very important factor to consider is the airflow
around cleanroom equipment.

The airflow split point must be analyzed carefully during the design process. Setting the split point incorrectly will lead to air
vortexes, which will disrupt the uniformity of the cleanroom's airflow. we stress the details, and strive to thoroughly
understand your operation. In this way we can ensure uniform airflow, thereby minimizing the risk of dust and bacteria
contamination.

How to Prevent Contamination
(1) Dust Generation
Due to the materials used in cleanroom-approved equipment, the amount of dust that they generate is negligible (only around 10% of
total dust generation.)
Humans, on the other hand, are a major source of dust particles. Although the evolution of materials and styles of clothing are
resulting in less and less dust being
produced on average, a static human being will produce as much dust as 8 m2 of flooring. The following are factors relevant to
dust production:
(A) Clothing Materials: Cotton produces the most dust of any common clothing material, followed by dacron, polyester, and then
nylon.
(B) Clothing Style: Looser clothing generally produces more dust.
(C) Movement: When in motion, humans produce 3-7 times more dust than when at rest.
(D) Detergent: Using detergent as opposed to regular water reduces dust generation by up to 500%

(2) Bacteria Generation
(A) Skin: Humans produce a new layer of skin about every four days. Every minute humans shed around 1,000 pieces of dead skin.
(B) Hair: Human hair is constantly falling out.
(C) Saliva: Saliva contains salt, enzymes, potassium, oxides, and food particles.
(D) A human at rest will produce at least 10,000 particles larger than 0.3µm per minute.
(E) A human whose head and torso are in motion will produce at least one million particles larger than 0.3µm per minute.
(F) A human walking at 0.9 m/s will produce at least five million particles larger than 0.3µm per minute.



Specification


item
value
Applicable Industries
Food & Beverage Factory, Other, Advertising Company, hospital
After Warranty Service
Online support
Local Service Location
Peru, Saudi Arabia, Indonesia, Pakistan, India, Russia, Spain, Thailand, Japan, Malaysia, Morocco, Kenya, Argentina, South Korea, Chile, Colombia, Algeria, Sri Lanka, Romania, Bangladesh, Kazakhstan, Ukraine, Kyrgyzstan, Nigeria, Uzbekistan
Showroom Location
None
Video outgoing-inspection
Provided
Machinery Test Report
Provided
Marketing Type
New Product 2020
Warranty of core components
1 Year
Core Components
PLC
Condition
New
Place of Origin
China
Warranty
1 Year
After-sales Service Provided
Online support
Application
Clean room
Air Filter
HEPA Air Filter
Feature
Install
Size
customized
Door
Electronically Interlocked


Packing & Delivery




To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.


Company Profile











Похожие товары

Новинки - Розница

0.0318 s.