STATE:Dear friends,our compnay has a large number of professional engineers,if you have questions about the technology of ATS,circuit breaker,ATS controller and isolation switch and their data,we can help you freely.my facebook have more picture and some product test and make video,if you interested it,please visit @chinaonetwothree. Thank you for your support.hope cooperation with you.
This product is SOCOMEC type it have all function.more client used for this product
What is an Automatic Transfer Switch (ATS)?
An automatic transfer switch transfers critical power loads to the most stable power source to ensure sustainable up time in mission-critical applications. Typical usage is in mission-critical applications where the power must stay on: hospitals, financial and data centers.
Features:
1) Provided with such protective functions as checking two sources of voltage at the same time, protection when any one phase or one phase above experiences under- or over-voltage, guide phase
2) When two sources haveATS (Automatic Transfer Switches )YES1-500S
Features:
1) Rated current of over current release: 40A,63A,80A,100A,125A,160A,200A,250A,315A,400A,500A
2) Pole number: 2p, 3p, 4p
3) Rated working voltage: AC 400V, 50Hz
4) The total height is only 110mm
5) Good function connection:UTILITY - UTILITY,UTILITY-GENERATOR
abnormal or faulty tripping (overload, short circuit), the controller won't send out the order to realize the protective function of reopening and closing
3) Four working modes: automatic control, common source (power supply I), standby power supply (power supply II), breaking electricity (re-tripping)
4) When the working mode is in the automatic control state, it has two self-throw no self-recover, self-throw, and self-recover functions:
a) Self-throw non-self recover: when the device enters the working state, power supply I automatically throws into supplying electricity; when power supply I has an abnormity, it will automatically transfer to power supply II; when power supply I recovers, it doesn't transfer until power supply II has an abnormity, then it will automatically transfer to power supply
b) Self-throw and self-recover: when the device enters the working state, the common source throws into supplying electricity; when power supply has an abnormity, it will automatically transfer to standby power supply; when common power supply recovers, it will automatically recover common power supply; but when the standby power supply has an abnormity, the controller will emit an alarm sound.