Voir®DeHum-ADC reliability testing
No. | Test item | Test condition | Judge standard |
1 | salt spray test | storage time:96h | No abnormality on surface, Dehumidification capacity at ±15% is considered qualified on before & after test |
2 | low temperature storage | temperature-40℃ storage time:96h | |
3 | high temperature storage | temperature85℃ storage time:96h | |
4 | High temperature and high humidity storage | temperature70℃ humidity:90% storage time:96h | |
5 | Temperature and humidity cycle | power source: 3V initial conditions:55℃,20% 24h;temperature:25℃⇔65℃ humidity:93±3%;Low temperature cycle :-10 (no humidity control)5 times | |
6 | thermal shock | temperature:-40℃~85℃ storage time:30min ,Cycle number :200cycle time conversion difference :2~3min | |
7 | Commercial frequency voltage resistance | Test voltage :AC1000V time :1 minute,test times :1 leakage current :5mA | no damaged on insulating layer |
Specific Application:
1. Museum display cabinet,Laboratory;
2. Power cabinet,Communication cabinet,Charging Pile;
3. Test device, Storage device,Other scenarios requiring constant temperature and constant time.
Benefits:
1. Auto-Control Dehumidification(low consumption);
2. Settable,flexible application;
3. RH:80%-20%;
4. The oxygen produced by electrolysis balances the loss pressure difference of moisture;
5. Does not affect seal level;
6. Easy installation and fast maintenance.