Specification | Integrated Rack X1 | Integrated Rack X1 IT Rack X1 | Integrated Rack X1 IT Rack X2 | Integrated Rack X1 IT Rack X3 | ||||
Item No. | DCA/B-16220-10403 | DCA/B-26220-10403 | DCA/B-26220-10406 | DCA/B-36220-10406 | DCA/B-26220-20810 | DCA/B-46220-20810 | DCA/B-46220-21215 | |
Rack System | Rack Quantity | 1 | 2 | 2 | 3 | 3 | 4 | 4 |
Expansion Method | All racks can be installed side by side, and the racks at both ends are equipped with side panels | |||||||
Configurable Power | 2.4KW | 2.4KW | 4.8KW | 4.8KW | 8KW | 8KW | 12KW | |
Rack System Size | 600*1200*2000mm | 1200*1200*2000mm | 1800*1200*2000mm | 2400*1200*2000mm | ||||
Rack Front Door | DCA: A single piece of steel is cut out for installation of monitoring screens and tempered glass; DCB: A whole piece of tempered glass with openings for the installation of the monitoring screen, with metal plate decoration on both sides | |||||||
Rear Door | Standard configuration: Steel plate door; dual-open steel door or dual-open mesh door for optional | |||||||
Rack Lock | Standard configuration: mechanical lock; Electrical lock and smart lock for optional | |||||||
Rack wheel&feet | No configuration; Rack wheel&feet for optional | |||||||
LED Light | There are three primary colors of red, green and blue RGB variable atmosphere lights on both sides of the front of the rack, and the top lighting of the rack is automatically switched after the door is opened. | |||||||
Powe Distribution System | Input | AC220V | AC380V | |||||
Input Master Switch | 63A/2P | 63A/2P | 63A/2P | 63A/2P | 63A/2P | 63A/2P | 40A/4P | |
Lightning protection level | 20KA/2P | 20KA/2P | 20KA/2P | 20KA/2P | 20KA/2P | 20KA/2P | 20KA/4P | |
PDU | Input current: 32A; output: 10-digit GB 10A+4-digit GB 16A; with junction box (For optional) | |||||||
Air Conditioning System | Cooling Capacity | 3.5KW | 7KW | 12.5KW | ||||
Emergency Settings | Front and rear top emergency ventilation system, (automatic pop-up door device can be selected with access control) | |||||||
Wind Circulation | The wind comes first; the return wind comes after | |||||||
UPS | UPS Capacity | 3KVA | 6KVA | 10KVA | 15KVA | |||
Input Voltage | AC220V | AC380V | ||||||
Input Wiring | Single in and single out | 3P+N wire + ground wire | ||||||
Battery Capacity | 72V*9AH | 192V*7AH | 192V*9AH | External battery, for optional | ||||
Backup time | 5-10 minutes for full load | |||||||
Battery Installation | UPS built-in battery | |||||||
Dynamic Environmental Monitoring System | Monitor Host | 5*485 ports, 2*232 ports, 2*network ports, 128M memory, 4G storage, 12*DI, 4*DO | ||||||
Monitoring Screens | Android tablet, 10.1" touch screen, 1280*800 | |||||||
Web Access | Web remote monitoring access function avaliable | |||||||
Temperature&Humidity Sensor | Same as number of racks | |||||||
Smoke Sensor | Same as number of racks | |||||||
Water Immersion Sensor | Same as number of Air Condition | |||||||
Video Surveillance | No configuration; Video surveillance for optional | |||||||
SMS Alarm | No configuration; SMS Alarm for optional | |||||||
APP | No configuration; APP for optional | |||||||
Fire Fighting System | Aerosol Fire Extinguishing Device | No configuration; Aerosol fire extinguishing device for optional |
1. Why choose Sunpln?
a. we are 17 years factory in producing data center infrastructure products.
b. we have 20+ people in quality management.
c. we have 50+ Process and R&D technicians.
d. we have 80000+ suquare meter factory area.
2. It takes how many days for products preparation?
20-30 days.
3. What's the trading term for selecting?
FOB, EXW, CIF, CFR, DDP, DDU.
4. I want to buy but I don't have any experience about international trading, what can I do?
Contact the sales for delivery door to door.
5. Which certification we have got?
For manufacturer: ISO 9001: 2008, OHSAS 18001, ISO 14001:2004