Вентилятор для лодки 5 кВт 4500 об/мин 24 В 56 в подшипник NSK редуктор управления электрическим мотоциклом скутером бесщеточный двигатель постоянного тока управление мотора стеклоочистителя


Поделиться:

Цена:220,00 $ - 300,00 $*
Стоимость в USD (на сегодня):Узнать

Количество:

Описание и отзывы

Характеристики



Product Display


_01.jpg


HF-MOTOR_01.jpgHF-motor_02.jpg
















































































Motor typeOutput PowerVoltageLoadSpeedRated TorqueEfficiencyNoiseIP Class
KWVARPMNm%dB
VOL-BL2K0B4824844.8030006.379362IP 54
VOL-BL2K0B7227229.8730006.379362IP 54
VOL-BL2K0B1102110 ac11.2930006.379362IP 54
VOL-BL2K0B2202220 ac5.6430006.379362IP 54
VOL-BL2K0B3802380 ac3.2730006.379362IP 54

 




HF-custom.jpg


 


motor.jpg


 


VIEW MORE PLS CONTACT US >>>


 


 





Other Products


_03.jpg



























Process Flow


_04.jpg 





About Us


_05.jpg_06.jpg 





Packing&Transport


_07.jpg


Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped. 


      What to do: Replace the fuse or reset the breaker.


 


     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
     What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.


 


     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
     What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.


 


      Likely cause: Controller may be defective.
      What to do: Verify voltage is coming out of the controller.


 


Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
     What to do: Verify that the motor is wired correctly.


 


     Likely cause: No output power from controller.
     What to do: Measure voltage coming from the controller.


 


     Likely cause: Motor is damaged and the armature is rubbing against the magnets.
     What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.


 


Q:  Motor takes too long to accelerate,what to do?
A:  Likely cause: Motor controller not properly set.
     What to do: Adjust the acceleration trim pot of the controller.


 


     Likely cause: Brushes are worn.
     What to do: Verify brush length.


 


     Likely cause: Bearings may be defective.
     What to do: Inspect bearings. Noisy or rough bearings should be replaced.


 


Q:  Motor runs in the wrong direction,what to do?
A:  Likely cause: Incorrect wiring
     What to do: Interchange the two motor leads.


 


Q:  Motor runs OK but has a clicking noise,what to do?
A:  Likely cause: Suspect a burr on the commutator.
     What to do: Remove burr from commutator using a commutator stone.